Aboveground Tank, Vessel & Piping Inspections in California
NDT Tanknicians provides API 653 and STI SP001 aboveground storage tank inspections, API 510 pressure vessel and API 570 piping inspections, and nondestructive testing for industrial facilities across California.
Or call 866-954-2915
Certified inspectors
API 653, API 510, API 570 and STI SP001
A written report for every job
Findings, thickness data and next-inspection dates
Inspectors nationwide
All 50 states, Canada and Mexico
What we inspect
- Large field-erected storage tanks: API 653 external, internal and out-of-service inspections
- Shop-built tanks, smaller field-erected tanks and portable containers: STI SP001 inspections
- Pressure vessels and air receivers: API 510 inspections of process vessels, air receivers and other pressure equipment
- Process and transfer piping: API 570 inspections, thickness surveys and remaining-life calculations
- Tank shells, welds and components: nondestructive testing by ultrasonic thickness, magnetic particle, dye penetrant, vacuum box and visual methods
- Tank coatings and linings: visual inspection and dry film thickness (DFT) testing
Not sure which standard applies? Tell us what the equipment is and what it stores; we’ll confirm the scope.
Inspections across California
We inspect tanks, pressure vessels and piping at refineries, fuel terminals and industrial plants across California.
California’s crude oil refineries are in the Los Angeles area, the Bay Area and Bakersfield. Products pipelines carry fuel from the Bay Area to Central Valley terminals and from the Los Angeles area to San Diego. Sites like these run fuel and chemical storage tanks, air receivers and process piping. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.
Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.
California requirements to plan around
- SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
- California’s Aboveground Petroleum Storage Act (APSA). A site with 1,320 gallons or more of petroleum in aboveground tanks of 55 gallons or more generally must have an SPCC plan, even if the federal rule does not apply, and must inspect its tanks periodically. The local CUPA inspects sites with 10,000 gallons or more at least every three years, and may inspect smaller sites. Some farms, nurseries, logging and construction sites follow lighter rules. California law (H&S Code §25270.4.5)
- Refinery process safety (Cal/OSHA). At petroleum refineries, pressure vessels, piping and other process equipment must be inspected and tested using procedures that meet or exceed recognized engineering practices, such as API codes. Cal/OSHA rule (8 CCR §5189.1)
Cities we serve in California
Tank inspection in Los Angeles · Sacramento, Stockton & Modesto · San Diego · San Francisco Bay Area · San Jose
What you receive and how to start
Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.
- Tell us what you have. Rough details are fine. You do not need to know which standard applies.
- We confirm the scope and send a quote.
- A certified inspector comes to your site.
- You receive the written report.
Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work
Frequently asked questions
Do I need to know which standard applies before asking for a quote?
No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.
Does the CUPA’s APSA inspection replace our own tank inspections?
No. At sites with 10,000 gallons or more of petroleum, the CUPA inspects at least once every three years to check that you meet APSA’s SPCC plan requirements. You still have to inspect your tanks periodically under that plan, and our API 653 and STI SP001 reports give you the records for those inspections.
Request an inspection quote
Send what you have; we will help with the rest. Helpful details:
- The tanks, vessels or piping, with approximate size or capacity
- What each one stores, and whether it is in service
- Your last inspection report, if you have one
- The site location and your timing
Or call 866-954-2915