Aboveground Tank, Vessel & Piping Inspections in Corpus Christi, TX
We inspect aboveground storage tanks, pressure vessels and process piping in Corpus Christi and the surrounding area. Send us your inspection request, and we’ll help confirm the scope.
Or call 866-954-2915
Certified inspectors
API 653, API 510, API 570 and STI SP001
A written report for every job
Findings, thickness data and next-inspection dates
Inspectors nationwide
All 50 states, Canada and Mexico
What we inspect
- API 653 tank inspection: external, internal and out-of-service inspections of field-erected tanks
- STI SP001 tank inspection: shop-fabricated tanks, smaller field-erected tanks and portable containers
- API 510 pressure vessel inspection: process vessels, air receivers and other pressure equipment
- API 570 piping inspection: process and transfer piping, thickness surveys and remaining-life calculations
- Nondestructive testing: ultrasonic thickness, magnetic particle, dye penetrant, vacuum box and visual testing
- Coating and lining inspection: visual inspection and dry film thickness (DFT) testing
Inspections for Corpus Christi-area facilities
We inspect tanks, pressure vessels and piping at refineries, crude oil terminals, chemical plants and other sites in Nueces and San Patricio counties.
Several petroleum refineries operate in Corpus Christi. The Port of Corpus Christi ships crude oil, most of it for export, from oil docks in the Inner Harbor and from private terminals at Ingleside. Chemical plants operate in Corpus Christi and in San Patricio County. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.
Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.
Texas requirements to plan around
- SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
- Large storage vessels. TCEQ’s Aboveground Storage Vessel Safety Program covers vessels of 21,000 gallons or more holding petroleum or other regulated substances at refineries, petrochemical plants and bulk storage terminals. Its standards adopt API 653’s tank evaluation and inspection sections, and TCEQ’s guidance has those inspections done or supervised by an API 653 authorized inspector, a certification our inspectors hold. Existing vessels must be registered by September 1, 2027, and certified compliant at their next regularly scheduled out-of-service maintenance after that date, no later than September 1, 2037. Texas rule (30 TAC 338.5)
What you receive and how to start
Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.
- Tell us what you have. Rough details are fine. You do not need to know which standard applies.
- We confirm the scope and send a quote.
- A certified inspector comes to your site.
- You receive the written report.
Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work · Tank inspection across Texas
Frequently asked questions
Do I need to know which standard applies before asking for a quote?
No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.
When does a refinery tank in Corpus Christi need to be certified under TCEQ’s storage vessel program?
If the vessel has a capacity of 21,000 gallons or more and stores a regulated substance, and no exemption applies, an existing vessel must be registered by September 1, 2027. It must then be certified compliant at its next regularly scheduled out-of-service maintenance after that date, and no later than September 1, 2037. After that, compliance is re-certified every 10 years. The owner or operator certifies compliance, and our API 653 inspection reports are condition records they can review.
Request an inspection quote
Send what you have; we will help with the rest. Helpful details:
- The tanks, vessels or piping, with approximate size or capacity
- What each one stores, and whether it is in service
- Your last inspection report, if you have one
- The site location and your timing
Or call 866-954-2915
