Aboveground Tank, Vessel & Piping Inspections in Florida

NDT Tanknicians provides API 653 and STI SP001 aboveground storage tank inspections, API 510 pressure vessel and API 570 piping inspections, and nondestructive testing for industrial facilities across Florida.

Or call 866-954-2915

Certified inspectors
API 653, API 510, API 570 and STI SP001

A written report for every job
Findings, thickness data and next-inspection dates

Inspectors nationwide
All 50 states, Canada and Mexico

What we inspect

Not sure which standard applies? Tell us what the equipment is and what it stores; we’ll confirm the scope.

Inspections across Florida

We inspect tanks, pressure vessels and piping at fuel terminals, airports and industrial plants across Florida.

Florida has no crude oil refineries. Petroleum products come in through marine terminals at several of the state’s ports, and two pipelines carry fuel from the Tampa Bay port area across central Florida to Orlando. Sites like these run fuel storage tanks, air receivers and process piping. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.

Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.

Florida requirements to plan around

  • SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
  • DEP tank registration. Chapter 62-762 covers aboveground tanks over 550 gallons that hold petroleum products or other regulated substances, with some exemptions, such as LP gas tanks. New tanks must be registered with DEP before they go into service, and the facility’s registration placard must be displayed in plain view. Florida rule (Chapter 62-762, F.A.C.)
  • Field-erected tank evaluations. Field-erected tanks must be evaluated when installed and re-tested on a schedule set under API 653. Each evaluation must be certified by a Florida-licensed professional engineer or approved by an API 653 certified inspector. The rule names API 653 certification, which our inspectors hold. Those under 250,000 gallons may be evaluated to STI SP001 instead, if the tank also falls within STI SP001’s scope. Florida rule (62-762.702, F.A.C.)

Cities we serve in Florida

Tank inspection in Miami & Fort Lauderdale · Orlando, Daytona Beach & Melbourne · Tampa, St. Petersburg & Sarasota

What you receive and how to start

Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.

  1. Tell us what you have. Rough details are fine. You do not need to know which standard applies.
  2. We confirm the scope and send a quote.
  3. A certified inspector comes to your site.
  4. You receive the written report.

Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work

Frequently asked questions

Do I need to know which standard applies before asking for a quote?

No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.

Can a smaller field-erected tank in Florida be evaluated to STI SP001 instead of API 653?

Florida allows this option for field-erected tanks under 250,000 gallons, provided the tank also falls within STI SP001’s scope. Larger field-erected tanks are evaluated to API 653, which also sets their re-testing schedule. Tell us the tank’s capacity, dimensions and how it was built, and we’ll confirm which standard fits.

Request an inspection quote

Send what you have; we will help with the rest. Helpful details:

  • The tanks, vessels or piping, with approximate size or capacity
  • What each one stores, and whether it is in service
  • Your last inspection report, if you have one
  • The site location and your timing