Aboveground Tank, Vessel & Piping Inspections in Lafayette, LA

We inspect aboveground storage tanks, pressure vessels and process piping in Lafayette and across Acadiana. Send us your inspection request, and we’ll help confirm the scope.

Or call 866-954-2915

Certified inspectors
API 653, API 510, API 570 and STI SP001

A written report for every job
Findings, thickness data and next-inspection dates

Inspectors nationwide
All 50 states, Canada and Mexico

What we inspect

Inspections for Lafayette-area facilities

We inspect tanks, pressure vessels and piping at oilfield service yards, fabrication shops, chemical and manufacturing plants, fuel terminals and other facilities across Lafayette and Acadiana.

Lafayette has long been a hub for energy production and services for the Gulf of Mexico, and the Port of Iberia to the south is home to oil and gas fabrication and marine service companies. Sites like these run fuel and lube-oil tanks, chemical storage, air receivers and process piping. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.

Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.

Louisiana requirements to plan around

  • SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
  • Louisiana SPC plans. Louisiana’s Spill Prevention and Control rule covers oil at the same 1,320-gallon threshold, counting containers of 55 gallons or more. It also covers listed liquid chemicals at 660 gallons in one container, or 1,320 gallons in a common storage area. Its guidelines call for aboveground tanks, including their foundations and supports, to be visually inspected by a competent person on a set schedule. Louisiana rule (LAC 33:IX, Chapter 9)

What you receive and how to start

Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.

  1. Tell us what you have. Rough details are fine. You do not need to know which standard applies.
  2. We confirm the scope and send a quote.
  3. A certified inspector comes to your site.
  4. You receive the written report.

Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work · Tank inspection across Louisiana

Frequently asked questions

Do I need to know which standard applies before asking for a quote?

No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.

Does a Louisiana facility need both an SPCC plan and an SPC plan?

They can be one document. Louisiana’s rule accepts an SPCC plan as part of the state plan, but the state plan must also cover any listed chemicals the federal rule leaves out. Our inspection reports give you the tank-condition records either plan calls for.

Request an inspection quote

Send what you have; we will help with the rest. Helpful details:

  • The tanks, vessels or piping, with approximate size or capacity
  • What each one stores, and whether it is in service
  • Your last inspection report, if you have one
  • The site location and your timing