Aboveground Tank, Vessel & Piping Inspections in Shreveport, LA
We inspect aboveground storage tanks, pressure vessels and process piping in Shreveport and across northwest Louisiana. Send us your inspection request, and we’ll help confirm the scope.
Or call 866-954-2915
Certified inspectors
API 653, API 510, API 570 and STI SP001
A written report for every job
Findings, thickness data and next-inspection dates
Inspectors nationwide
All 50 states, Canada and Mexico
What we inspect
- API 653 tank inspection: external, internal and out-of-service inspections of field-erected tanks
- STI SP001 tank inspection: shop-fabricated tanks, smaller field-erected tanks and portable containers
- API 510 pressure vessel inspection: process vessels, air receivers and other pressure equipment
- API 570 piping inspection: process and transfer piping, thickness surveys and remaining-life calculations
- Nondestructive testing: ultrasonic thickness, magnetic particle, dye penetrant, vacuum box and visual testing
- Coating and lining inspection: visual inspection and dry film thickness (DFT) testing
Inspections for Shreveport-area facilities
We inspect tanks, pressure vessels and piping at refineries, chemical and lubricant plants and gas production sites in Shreveport and across Caddo and Bossier parishes.
A refinery operates in the city, and refineries also operate nearby in Princeton and Cotton Valley. Chemical and lubricating oil plants operate elsewhere in Caddo Parish.
Shreveport also sits in the Haynesville natural gas region of Louisiana and Texas, where Louisiana’s exploration has centered on Caddo, Bossier, DeSoto and Red River parishes. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.
Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.
Louisiana requirements to plan around
- SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
- Fire code. Within the City of Shreveport, the city code adopts NFPA 1, the National Fire Protection Association’s fire code, and its mandatory referenced codes, including the NFPA 30 flammable and combustible liquids code. NFPA 30 calls for steel storage tanks to be inspected and maintained to API 653 or STI SP001, whichever applies. Shreveport Code of Ordinances (§ 30-55)
- Oil and gas production sites. Louisiana’s water quality rule for oil and gas exploration and production requires a Spill Prevention and Control plan with a program for regular inspection of all storage tanks, separators and related production and transfer equipment. Inspection and test records must be kept for at least three years. Louisiana rule (LAC 33:IX.708)
What you receive and how to start
Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.
- Tell us what you have. Rough details are fine. You do not need to know which standard applies.
- We confirm the scope and send a quote.
- A certified inspector comes to your site.
- You receive the written report.
Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work · Tank inspection across Louisiana
Frequently asked questions
Do I need to know which standard applies before asking for a quote?
No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.
Do we need a city permit to store fuel in an aboveground tank in Shreveport?
Inside city limits, usually yes. The Shreveport Fire Department’s tank permit covers storing Class I liquids in excess of 5 gallons inside a building or 10 gallons outside, and Class II or III liquids in excess of 25 gallons inside or 60 gallons outside, except fuel oil used with oil-burning equipment. The Fire Prevention Division approves the permit and in most cases inspects the site first. Our API 653 and STI SP001 reports document the tank’s condition for the facility’s records.
Request an inspection quote
Send what you have; we will help with the rest. Helpful details:
- The tanks, vessels or piping, with approximate size or capacity
- What each one stores, and whether it is in service
- Your last inspection report, if you have one
- The site location and your timing
Or call 866-954-2915
