Aboveground Tank, Vessel & Piping Inspections in South Carolina
NDT Tanknicians provides API 653 and STI SP001 aboveground storage tank inspections, API 510 pressure vessel and API 570 piping inspections, and nondestructive testing for industrial facilities across South Carolina.
Or call 866-954-2915
Certified inspectors
API 653, API 510, API 570 and STI SP001
A written report for every job
Findings, thickness data and next-inspection dates
Inspectors nationwide
All 50 states, Canada and Mexico
What we inspect
- Large field-erected storage tanks: API 653 external, internal and out-of-service inspections
- Shop-built tanks, smaller field-erected tanks and portable containers: STI SP001 inspections
- Pressure vessels and air receivers: API 510 inspections of process vessels, air receivers and other pressure equipment
- Process and transfer piping: API 570 inspections, thickness surveys and remaining-life calculations
- Tank shells, welds and components: nondestructive testing by ultrasonic thickness, magnetic particle, dye penetrant, vacuum box and visual methods
- Tank coatings and linings: visual inspection and dry film thickness (DFT) testing
Not sure which standard applies? Tell us what the equipment is and what it stores; we’ll confirm the scope.
Inspections across South Carolina
We inspect tanks, pressure vessels and piping at fuel terminals, chemical plants and manufacturing plants across South Carolina.
South Carolina has no refineries. Most fuel enters the state through the Port of Charleston or by two refined product pipelines from the Gulf Coast, which deliver at several locations in the state. The state’s manufacturers make chemicals, plastics and rubber, paper and motor vehicles. Sites like these run fuel and chemical storage tanks, air receivers and process piping. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.
Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.
South Carolina requirements to plan around
- SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
- SCDES and aboveground tanks. The South Carolina Department of Environmental Services (SCDES) does not regulate aboveground storage tank systems. It points owners to the federal SPCC requirements. SCDES aboveground tank page
- State fire code. The State Fire Marshal’s regulations make the International Fire Code, as adopted by the South Carolina Building Codes Council, the minimum fire safety standard statewide. Its flammable liquids chapter requires aboveground tanks, connected piping and ancillary equipment to be maintained in a safe operating condition. The 2021 edition applies now; local jurisdictions move to the 2024 edition on January 1, 2027. South Carolina rule (Regulation 71-8300)
What you receive and how to start
Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.
- Tell us what you have. Rough details are fine. You do not need to know which standard applies.
- We confirm the scope and send a quote.
- A certified inspector comes to your site.
- You receive the written report.
Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work
Frequently asked questions
Do I need to know which standard applies before asking for a quote?
No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.
Does South Carolina regulate aboveground storage tanks?
Not through a state tank program. SCDES does not regulate aboveground storage tank systems and points owners to the federal SPCC rule, whose inspection program usually follows API 653 or STI SP001. The state fire code still applies to flammable and combustible liquid tanks and requires tanks and connected piping to be kept in a safe operating condition. Our API 653 and STI SP001 reports give you the findings, thickness data and next-inspection dates for the facility’s records.
Request an inspection quote
Send what you have; we will help with the rest. Helpful details:
- The tanks, vessels or piping, with approximate size or capacity
- What each one stores, and whether it is in service
- Your last inspection report, if you have one
- The site location and your timing
Or call 866-954-2915
