Aboveground Tank, Vessel & Piping Inspections in Orlando, Daytona Beach & Melbourne, FL
We inspect aboveground storage tanks, pressure vessels and process piping in Orlando and across Central Florida. Send us your inspection request, and we’ll help confirm the scope.
Or call 866-954-2915
Certified inspectors
API 653, API 510, API 570 and STI SP001
A written report for every job
Findings, thickness data and next-inspection dates
Inspectors nationwide
All 50 states, Canada and Mexico
What we inspect
- API 653 tank inspection: external, internal and out-of-service inspections of field-erected tanks
- STI SP001 tank inspection: shop-fabricated tanks, smaller field-erected tanks and portable containers
- API 510 pressure vessel inspection: process vessels, air receivers and other pressure equipment
- API 570 piping inspection: process and transfer piping, thickness surveys and remaining-life calculations
- Nondestructive testing: ultrasonic thickness, magnetic particle, dye penetrant, vacuum box and visual testing
- Coating and lining inspection: visual inspection and dry film thickness (DFT) testing
Inspections for Central Florida facilities
We inspect tanks, pressure vessels and piping at fuel terminals, port facilities and other industrial sites in Orange, Seminole, Osceola, Lake, Volusia and Brevard counties.
Two pipelines carry petroleum products and fuel ethanol from the Tampa Bay port area to Orlando, and a pipeline terminal stores fuel in Orlando. On the coast, Port Canaveral handles petroleum as bulk cargo, and petroleum terminals operate at the port. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.
Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.
Florida requirements to plan around
- SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
- Field-erected tank evaluations. Field-erected tanks must be evaluated when installed and re-tested on a schedule set under API 653. Each evaluation must be certified by a Florida-licensed professional engineer or approved by an API 653 certified inspector. The rule names API 653 certification, which our inspectors hold. Field-erected tanks with a storage capacity of less than 250,000 gallons may be evaluated to STI SP001 instead, if the tank also falls within STI SP001’s scope. Florida rule (62-762.702, F.A.C.)
- Fire code. Florida’s statewide fire code, the Florida Fire Prevention Code, adopts NFPA 30, the flammable and combustible liquids code. NFPA 30 calls for steel storage tanks to be inspected and maintained to API 653 or STI SP001, whichever applies. Florida rule (69A-60.005, F.A.C.)
What you receive and how to start
Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.
- Tell us what you have. Rough details are fine. You do not need to know which standard applies.
- We confirm the scope and send a quote.
- A certified inspector comes to your site.
- You receive the written report.
Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work · Tank inspection across Florida
Frequently asked questions
Do I need to know which standard applies before asking for a quote?
No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.
Who checks our tank records for DEP in the Orlando area?
DEP contracts its storage tank compliance inspections to local programs. Orange County’s Environmental Protection Division covers Orange, Lake, Osceola, Seminole and Volusia counties, and Brevard County’s Natural Resources Management Department covers Brevard. Florida’s tank rule has you keep the results of internal inspections and nondestructive testing until the tank system is closed, and make your records available for inspection by DEP or the county. Our API 653 and STI SP001 reports give you dated condition records those inspectors can review.
Request an inspection quote
Send what you have; we will help with the rest. Helpful details:
- The tanks, vessels or piping, with approximate size or capacity
- What each one stores, and whether it is in service
- Your last inspection report, if you have one
- The site location and your timing
Or call 866-954-2915
