Aboveground Tank, Vessel & Piping Inspections in St. Louis, MO
We inspect aboveground storage tanks, pressure vessels and process piping in St. Louis and the surrounding area. Send us your inspection request, and we’ll help confirm the scope.
Or call 866-954-2915
Certified inspectors
API 653, API 510, API 570 and STI SP001
A written report for every job
Findings, thickness data and next-inspection dates
Inspectors nationwide
All 50 states, Canada and Mexico
What we inspect
- API 653 tank inspection: external, internal and out-of-service inspections of field-erected tanks
- STI SP001 tank inspection: shop-fabricated tanks, smaller field-erected tanks and portable containers
- API 510 pressure vessel inspection: process vessels, air receivers and other pressure equipment
- API 570 piping inspection: process and transfer piping, thickness surveys and remaining-life calculations
- Nondestructive testing: ultrasonic thickness, magnetic particle, dye penetrant, vacuum box and visual testing
- Coating and lining inspection: visual inspection and dry film thickness (DFT) testing
Inspections for St. Louis-area facilities
We inspect tanks, pressure vessels and piping at fuel terminals, chemical and coatings plants, river terminals and other facilities in St. Louis, St. Charles and Jefferson counties in Missouri and in the Illinois Metro East.
The city’s port district runs along its Mississippi River frontage, with barge-transfer facilities for bulk cargo. Several petroleum bulk terminals sit on South First Street in south St. Louis. Chemical, plastic resin and paint and coatings plants operate across the area. These sites run fuel and chemical storage tanks, air receivers and process piping. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.
Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.
Missouri-side requirements to plan around
- SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
- State fuel-site safety inspections. Missouri Department of Agriculture inspectors visit service stations, bulk fuel storage facilities, airports and barge and pipeline terminals every six months. They check the piping and electrical work for fuel dispensing systems and aboveground tanks against Missouri’s rules and the 1996 editions of NFPA 30 and 30A. Missouri Department of Agriculture
What you receive and how to start
Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.
- Tell us what you have. Rough details are fine. You do not need to know which standard applies.
- We confirm the scope and send a quote.
- A certified inspector comes to your site.
- You receive the written report.
Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work · Tank inspection across Missouri
Frequently asked questions
Do I need to know which standard applies before asking for a quote?
No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.
Do Missouri’s state fuel-site inspections replace SPCC tank inspections?
No, they are separate requirements. Missouri Department of Agriculture inspectors check fuel sites every six months for safety and fire-code compliance, including the piping and electrical work for aboveground tanks. If your facility needs an SPCC plan, the federal rule separately requires each aboveground container to be tested or inspected for integrity on a regular schedule, following industry standards, which for most tanks means API 653 or STI SP001. Our inspection reports document each tank’s condition for your SPCC records.
Request an inspection quote
Send what you have; we will help with the rest. Helpful details:
- The tanks, vessels or piping, with approximate size or capacity
- What each one stores, and whether it is in service
- Your last inspection report, if you have one
- The site location and your timing
Or call 866-954-2915
