Aboveground Tank, Vessel & Piping Inspections in Tampa, St. Petersburg & Sarasota, FL
We inspect aboveground storage tanks, pressure vessels and process piping throughout Tampa Bay and Sarasota. Send us your inspection request, and we’ll help confirm the scope.
Or call 866-954-2915
Certified inspectors
API 653, API 510, API 570 and STI SP001
A written report for every job
Findings, thickness data and next-inspection dates
Inspectors nationwide
All 50 states, Canada and Mexico
What we inspect
- API 653 tank inspection: external, internal and out-of-service inspections of field-erected tanks
- STI SP001 tank inspection: shop-fabricated tanks, smaller field-erected tanks and portable containers
- API 510 pressure vessel inspection: process vessels, air receivers and other pressure equipment
- API 570 piping inspection: process and transfer piping, thickness surveys and remaining-life calculations
- Nondestructive testing: ultrasonic thickness, magnetic particle, dye penetrant, vacuum box and visual testing
- Coating and lining inspection: visual inspection and dry film thickness (DFT) testing
Inspections for Tampa Bay-area facilities
We inspect tanks, pressure vessels and piping at fuel terminals, fertilizer plants, port facilities and other sites from Pasco County south to Sarasota County.
Port Tampa Bay brings in petroleum products for west and central Florida, and much of it moves on by pipeline. Petroleum terminals operate on Hooker’s Point and Pendola Point. The port also ships phosphate fertilizer from the central Florida mining district, and phosphate fertilizer plants operate in eastern Hillsborough County. API 653 commonly applies to larger field-erected steel tanks; STI SP001 commonly applies to shop-built and certain smaller field-erected tanks.
Whatever your equipment stores, our inspections find corrosion and other damage early, so you can plan maintenance and stay on schedule.
Florida requirements to plan around
- SPCC plans. A facility may need an SPCC plan if its total aboveground oil storage capacity is more than 1,320 gallons, counting only containers of 55 gallons or more, and a spill could reach waterways. The plan’s inspection program usually follows API 653 or STI SP001. EPA rule (40 CFR 112.1)
- Field-erected tank evaluations. Field-erected tanks must be evaluated when installed and re-tested on a schedule set under API 653. Florida Rule 62-762.702(6) allows the required field-erected tank evaluation to be approved by an API 653-certified inspector, as an alternative to certification by a Florida-licensed professional engineer. The rule names API 653 certification, which our inspectors hold. Field-erected tanks smaller than 250,000 gallons may be evaluated to STI SP001 instead, if the tank also falls within STI SP001’s scope. Florida rule (62-762.702, F.A.C.)
What you receive and how to start
Every inspection ends with a written report: findings, thickness data and recommended next-inspection dates, ready for your SPCC plan or integrity program.
- Tell us what you have. Rough details are fine. You do not need to know which standard applies.
- We confirm the scope and send a quote.
- A certified inspector comes to your site.
- You receive the written report.
Our inspectors hold API 653, API 510, API 570 and STI SP001 certifications, our NDT technicians are certified, and our crews are OSHA 10, 30 and 40-hour trained. We are based near Kansas City, MO, with a network of inspectors serving all 50 states, Canada and Mexico. Our inspectors’ certifications · Where we work · Tank inspection across Florida
Frequently asked questions
Do I need to know which standard applies before asking for a quote?
No. Tell us what the equipment is, what it stores and roughly how big it is. We will confirm whether API 653, STI SP001, API 510, API 570 or your SPCC plan sets the scope.
When does a field-erected tank in Florida need its API 653 evaluation?
Florida requires the first evaluation when the tank is installed. After that, re-testing follows the schedule established under API 653. The evaluation can be approved by an API 653-certified inspector, as an alternative to certification by a Florida-licensed professional engineer; the rule names API 653 certification, which our inspectors hold. Send us the tank’s capacity, what it stores and the date of its last evaluation, and we’ll confirm the scope.
Request an inspection quote
Send what you have; we will help with the rest. Helpful details:
- The tanks, vessels or piping, with approximate size or capacity
- What each one stores, and whether it is in service
- Your last inspection report, if you have one
- The site location and your timing
Or call 866-954-2915
